Blue Icon (Tianjin) Technology Co., Ltd.
Blue Icon (Tianjin) Technology Co., Ltd.

Products

Contact Us

Can You Use an Existing CCTV Camera in an Explosion-Protected Housing?

If your existing CCTV camera fits inside an explosion-protected housing, you’ve confirmed the dimensions. To use it in a hazardous area, verify that the equipment certification covers the assembled camera, housing, and cable entry configuration. Under IECEx, a certificate number ending in U identifies a component certificate. Once the camera is installed, check the certification documents for the complete assembly. IECEx Certified Equipment Scheme

Identify the Hazard the Housing Must Address

A CCTV housing needs a front window for the camera’s field of view and a cable entry for power or Ethernet. For a model that uses Ex d flameproof protection, check the model-specific documentation for the window assembly, enclosure joints, and cable entries. If a flammable mixture ignites inside, the enclosure must withstand the resulting pressure and prevent the explosion from propagating into the surrounding explosive gas atmosphere. IEC 60079-1 · EU ATEX Directive 2014/34/EU, Annex II

If the installation involves combustible dust, check the dust protection marking and the equipment’s surface temperature limits. Ex t reduces the risk of dust ignition through enclosure protection and limits on surface temperature. IP66 describes protection against dust and water ingress. For example, BIT-CCTV lists IP66 as an ingress protection rating for its single-compartment aluminum camera housing. To determine whether a specific model is suitable for a hazardous area, check its Ex marking and certification documents. BIT-CCTV Camera Housings · IEC 60079-31 · IEC 60529

Check What the IECEx Certificate Covers

Look up the certificate number in the official IECEx database. Then match the equipment name, model, and configuration described in the certificate and its annexes to what you’ll actually receive. A Current status means the certificate is valid. The scope and conditions tell you whether it covers your assembly. IECEx Certificate Lookup Guidance

What the certificate showsWhat to check next
The number ends in UThis is an Ex component certificate. Read the component’s limitations and ask the equipment manufacturer or integrator for certification documents covering the finished assembly.
The equipment certificate number ends in XRead the specific conditions of use in the certificate and its annexes. Even when the model matches, the installation must meet those conditions.
The equipment certificate explicitly covers the proposed configurationCheck the Ex marking against the project’s certification requirements and the site’s area classification, gas or dust group, temperature requirements, and ambient temperature range.

IECEx Guidance on Certificate Numbers and Suffixes

What Should You Recheck When Replacing a Camera With One the Same Size?

Suppose the original camera is discontinued. Its replacement fits the same bracket, but it has a wider-angle lens and uses Power over Ethernet (PoE) instead of a separate DC supply. Start with the assembly drawing and check where the lens sits relative to the front window. The camera body may fit while the window frame cuts off the edges of the image.

Then give the equipment manufacturer or integrator the replacement model, its maximum power consumption, and its power supply method. Use the equipment documentation to verify the heat load, cable routing and entry method, and the cable glands and blanking plugs supplied with the unit. Cameras with the same dimensions can generate different amounts of heat and require different cable entry configurations. BIT-CCTV Guidance on Hazardous-Area Camera Housing Fit · IECEx Guidance on Design Changes to Certified Equipment

Before finalizing the configuration, put the camera and lens models, power supply method, maximum power consumption, cable entry configuration, and site conditions on one list. Ask the manufacturer or integrator to identify the certificate number and the relevant annex entries. If you only have a component certificate for the housing, or the equipment documents don’t establish coverage for the replacement configuration, have the complete assembly assessed before putting it into service in the hazardous area. IECEx Certified Equipment Scheme