The shell with the label “atex camera enclosure (ATEX explosion-proof camera cover)” looks no different from the ordinary industrial protective cover we usually use at first glance. Don't assume that if it uses an all-metal casing, has tightly punched seams, or has an exceptionally high water and dust resistance rating, it can be thrown directly into a dangerous area (i.e., an explosive environment). Whether it can be used depends entirely on how the specific model is defined in the certificate. It is also necessary to confirm whether it has violated the structural requirements specified on the certificate after the equipment inside is installed on site.
image.png

Don't just stare at the dangerous area, look at the full set of explosion-proof signs

The division of dangerous areas on site only indicates how often explosive environments occur in that area. This alone cannot determine whether the shield can be used. Gas category, dust type, equipment protection level (EPL), explosion-proof type, temperature group, plus ambient temperature and special conditions with “X” in the certificate ——any of these parameters are not correct, and the matching result must be overturned and repeated. Many people on the market use “explosion-proof shields” with their mouths open and closed, but the doorway inside has become deeper: explosion-proof, dust-proof, and positive pressure-proof. The principles are completely different. You absolutely cannot use the usage conditions of model A to hard cover model B.

When checking the certificate, be sure to check three points: the manufacturer, the complete model, and the specific version that needs to be installed on site. It is also necessary to verify the implementation standards, issuing institutions, and whether it is still in effect. Don't use the certification icon hanging on the manufacturer's website to make a fuss, and don't use certificates from other products of the same brand to misrepresent them. That won't prove the compliance of the shield itself. Do you expect that just a few letters printed on the casing “explosion-proof” or “ATEX” can cover the entire world and cover all the complex working conditions on site? That was pure fantasy.

Conventional protection levels solve another problem

Many people who work on-site tend to confuse concepts. IP rating (such as the common IP66) is simply the ability of the shell to be gray-proof and waterproof, while IK rating is based on resistance to damage; but explosion-proof certification in dangerous areas is based entirely on another set of safety logic. You can't assume that a shield labeled IP66 naturally comes with explosion-proof, dust-proof, or positive pressure-proof properties. Similarly, stainless steel is just a material description and cannot replace explosion-proof certification at all.

In addition, the term “with pressure” is also very misleading. The original intention of a regular inflatable or positively pressurized shell was just to keep out dirt and moisture from the outside. However, in the field of explosion-proof, the well-established positive pressure explosion-proof “p” has dead rules for product structure, gas replacement process, real-time monitoring and testing. If you really want to use this explosion-proof type, you must finalize the working pressure, the ventilation volume of the protective gas, the leakage rate, the flow rate, as well as the safety logic of alarms and power outages according to the specific equipment installed inside. If you get carried away and throw an ordinary pressurized shield directly into the danger zone, it's like frantically testing the red line of safety certification.

Once the camera is installed, do not tamper with the authentication structure

Just because an empty shell itself has a certificate doesn't mean you can just plug a camera and lens into it with your eyes closed. Whether it's a camera, lens, or internal electrical load, it must be kept within the limits allowed by the certificate. After the entire set is installed, the interior of the shell must leave enough room for the lens to zoom and extend, the direction of the plug-in must be smooth, and the effective light-transmitting area of the front panel glass must also be aligned with the field of view angle of the lens and cannot be blocked.

There is another particularly easy place to start on-site work: cable introduction devices (such as explosion-proof grands), plugs, flange joint surfaces and various fastening screws. These spare parts are all part of the explosion-proof certification structure. You must not make it easy to follow the wiring. Just find ordinary accessories bought from a hardware store and replace them. Even if you only slightly change the configuration of the lower window, sealing sleeve or joint, the explosion-proof performance of the entire device may be completely destroyed. Whether it's your first installation, opening the cover for inspection, replacing parts, or routine maintenance, you must follow the certificate and manufacturer's instructions step by step. If you are using a positive pressure system, you must perform gas replacement according to the rules and confirm that the pressure meets the standard before powering on; once the pressure drops or an abnormality occurs during operation, you must strictly follow the safety procedures, which are interlocked and power cut off.

Ultimately, what needs to be accepted and verified on site is a “complete equipment” that has been equipped with real cameras and lenses and fully assembled in accordance with explosion-proof certification requirements. It should never just be an empty shell with the English letters “ATEX” printed on it.